Hafele Hardware Technology

Häfele Beschlagtechnik
Customer Service
Hafele America Co.
7:30 a.m. to 8:00 p.m. EST
Tel : 1.800.423.3531
Fax: 1.800.325.6197
Contact us
Find a Sales Rep
Search for a sales rep near you
Consumers - looking for Hafele online retailers? Check here

Dialock FAQs

Q: Can I spray paint the DTSH?

A: Hafele would be happy to custom paint the DTSH to your specifications. From pin striping to racing flames we can customize the look of the DTSH for your project. If you decide to paint it yourself it takes some patiner's tape and skill to avoid painting the sensitive parts. If you do paint the DTSH you are accepting full risk for any damage caused to the unit. We reserve the right to refuse any return due to improper painting of the DTSH. 
back to index back to index

Q: What frequency is used for this transponder?

A: TI-ris: 134kHz, Legic: 15.6mHz
back to index back to index

Q: How far can a key be placed and still be read at the door terminal?

A: The reading distance is 3 -100cm ( 1 in - 3 feet) depending on antenna.
back to index back to index

Q: What are the features of the transponder keys?

A: Factory code – 32-digit code, 4.3 billion original codes.1,000 Bit (128 digit) storage space: storage for 4 keys + cash value.
back to index back to index

Q: How many lock cycles can be performed before the batteries need changing in a LockerLock?

A: Typically, batteries should be changed at 10,000 lock cycles.

Test 1:
1 opening & closing every 10 seconds
Test was stopped because of mechanical problems at 65,884 movements
Remaining voltage of the batteries: 5.11 volts

Test 2:
1 opening & closing every 7.5 seconds
After 39,676 activations the batteries were empty.

Test 3:
1 opening & closing every 7.5 seconds
After 36,954 activations the batteries were empty.

back to index back to index

Q: How many keys can be stored in a single LockerLock Terminal?

A:
  • LockerLock - Configured for Simple (Stand alone) programming: 30 keys.
  • LockerLock - Configured for Complete (Configuration transponder) programming: A combination maximum 29 “personnel” and 1 “guest” keys.
  • LockerLock - Configured for wellness mode: A combination maximum 29 “emergency/manager’s” and 1 “user” keys
back to index back to index

Related links