APPLICATION GUIDELINES
Application temperature: Above 40°F
Service temperature: -40°F to 180°F
Methods of application: Cartridge/caulking gun
Working time: Approximately 15 minutes for a 1/4” bead.
Working surfaces: For best results, surfaces must be cleaned down to the original substrate, dry and free from any material that may deter adhesion.
Cleanup: Clean tools and excess material with soap and water before it dries. Remove cured sealant by cutting with a sharp-edged tool.
LIMITATIONS
Do not apply if rain is expected within 12 hours. Air, sealant, and surface temperature should be above 40°F. Allow at least 2 hours of drying time before painting with acrylic or elastomeric coatings. If joint depth exceeds 1/4”, use backing material. Not designed for continuous submersion or use below the waterline. Do not use for aquariums.
Note
Titebond UA 920 Clear (8741) will be white during application but will clear within 7-14 days, depending on temperature, humidity and bead size.